3.4.8 Configuring Channel #0 Temperature Source
Program this parameter to match the desired instance number of the temperature reading for
this channel. You can program this parameter to any value between 0 and 252. The default
value for this parameter is 129 (User Defined).
3.4.9 Configuring Channel #0 Temperature Label
Program this parameter with a text string which identifies the particular temperature parameter
being monitored by this channel. Maretron display products will display this label text when
you are selecting data to display.
3.5 Configuring Channel #1
3.5.1 Enabling/Disabling Channel #1
NOTE: This parameter is available only when the Operating Mode of the FFM100 is set to
“Two Independent Flow Rates”.
By default, the channel is enabled and will measure the flow rate and transmit it over the
NMEA 2000 network. If this parameter is programmed to “Disable”, the channel will be
completely disabled and will not measure flow rate nor transmit it over the NMEA 2000
network.
3.5.2 Configuring Channel #1 Engine Instance
NOTE: This parameter is available only when the Operating Mode of the FFM100 is set to
“Two Independent Flow Rates”.
Program this parameter to match the desired engine instance number of the flow rate and total
fuel used for this channel. You can program this parameter to any value between 0 and 252.
3.5.3 Configuring Channel #1 Engine Label
NOTE: This parameter is available only when the Operating Mode of the FFM100 is set to
Two Independent Flow Rates”.
Program this parameter with a text string which identifies the particular parameter being
monitored by this channel. Maretron display products will display this label text when you are
selecting data to display.
3.5.4 Configuring Channel #1 K-factor
Program this parameter to match the K-factor that appears on the flow sensor connected to
this channel.
3.5.5 Configuring Channel #1 Temperature Coefficient
NOTE: This parameter is available only when the Operating Mode of the FFM100 is set to
Differential Mode”.