
Revision 1.0 Page i ®® DCM100 DC Monitor User’s Manual Revision 1.0 Copyright © 2008 Maretron, LLP All Rights Rese
DCM100 User’s Manual Page 6 Revision 1.0 Period, 17) Zero Current Threshold, 18) Manually Set Battery to 100%, 19) Current Sensor Zero Offset
Revision 1.0 Page 7 ®®2.5.4.3 Equalization You may indicate here whether or not the battery supports equalization. This is used only for r
DCM100 User’s Manual Page 8 Revision 1.0 available, you can set this parameter to the estimated battery temperature, between -25°C and 125°C.
Revision 1.0 Page 9 ®®3.1 Parameters Common to DC Sources and Batteries The parameters in this section are transmitted regardless of the “
DCM100 User’s Manual Page 10 Revision 1.0 4 Background 4.1 Why Monitor Batteries? The lifetime and storage capacity of batteries can be gr
Revision 1.0 Page 11 ®®4.5 Battery Safety Precautions 1. Lead-acid batteries generate explosive gases during operation. Make sure that t
DCM100 User’s Manual Page 12 Revision 1.0 restated version of the equation, which allows you to calculate the time to totally discharge a gi
Revision 1.0 Page 13 ®® • Clean the unit with a soft cloth. Do not use chemical cleaners as they may remove paint or markings or may corr
DCM100 User’s Manual Page 14 Revision 1.0 automatically void the warranty. If service is required, please return the unit to an authorized M
Revision 1.0 Page 15 ®®Environmental Parameter Value IEC 60954 Classification Exposed Degree of Protection IP64 Operating Temperature -
DCM100 User’s Manual Page ii Revision 1.0 Revision History Revision Description 1.0 Original document
DCM100 User’s Manual 10 Installation Template Please check the dimensions before using the following diagram as a template for drilling the mounti
Revision 1.0 Page 17 ®®11 Maretron (2 Year) Limited Warranty Maretron warrants the DCM100 to be free from defects in materials and workmans
Revision 1.0 Appendix A – NMEA 2000 Interfacing Page A1 ®®Appendix A – NMEA 2000® Interfacing DCM100 NMEA 2000® Periodic Data Transmitted
DCM100 User’s Manual Page A2 Appendix A – NMEA 2000 Interfacing Revision 1.0 PGN 127508 – Battery Configuration Status The DCM100 uses this P
Revision 1.0 Page iii ®®Table of Contents 1 Introduction ...
DCM100 User’s Manual Page iv Revision 1.0 4.3 Battery Capacity ...
Revision 1.0 Page 1 ®®1 Introduction Congratulations on your purchase of the Maretron DC Monitor (DCM100). Maretron has designed and buil
DCM100 User’s Manual Page 2 Revision 1.0 2 Installation 2.1 Unpacking the Box When unpacking the box containing the Maretron DCM100, you sh
Revision 1.0 Page 3 ®®2.3 Mounting the DCM100 Attach the DCM100 securely to the vessel using the included stainless steel mounting screws
DCM100 User’s Manual Figure 2 – NMEA 2000® Connector Face Views 2.4.2 Connecting the DC power and Sensor Connections The DCM100’s DC Power and
Revision 1.0 Page 5 ®®e. Disconnect the wire from the positive terminal of the battery or other DC source that is being monitored and plac
Komentarze do niniejszej Instrukcji