Revision 1.3 Page 15
®®
Figure 9 – Troubleshooting Guide
If these steps do not solve your problem, please contact Maretron Technical Support (refer to
Section 7 for contact information).
6 Technical Specifications
Specifications (Tank Level Mode)
Parameter Value Comment
Accuracy +/-1% FS Exclusive of Pressure Transducer
Resolution +/-0.33% FS Over Full Pressure Transducer Range
Number of Tank Types 16 Fuel, Fresh Water, Waste water, Live well, Oil, etc.
Number of Tanks per Tank Type 16 16 Tanks per Tank Type Numbered 0-15
Support for Irregularly Shaped
Tanks
Yes Can be Calibrated for any Shape Tank
Programmable Tank Capacity Yes Allows Displays to Calculate Amount Remaining
Specifications (Pressure/Vacuum Mode)
Parameter Value Comment
Accuracy +/-1% FS Exclusive of Pressure Transducer
Resolution +/-0.33% FS Over Full Pressure Transducer Range
Number of Pressure Source Types 21 Water Pressure, Atmospheric Pressure, Compressed Air
Pressure, Hydraulic Pressure, Steam Pressure, 16 User
Defined Sources
Certifications
Parameter Comment
NMEA 2000 Level A
Maritime Navigation and Radiocommunication Equipment & Systems IEC 61162-3
Maritime Navigation and Radiocommunication Equipment & Systems Tested to IEC 60945
FCC and CE Mark Electromagnetic Compatibility
NMEA 2000
®
Parameter Group Numbers (PGNs) - See Appendix A for Details
Description PGN # PGN Name Default Rate
Periodic Data PGNs 127505 Fluid Level 0.4 Times/Second
130314 Actual Pressure 0.5 Times/Second
Response to Requested PGNs 126464 PGN List (Transmit and Receive) N/A
126996 Product Information N/A
126998 Configuration Information N/A
Protocol PGNs 059392 ISO Acknowledge N/A
059904 ISO Request N/A
060928 ISO Address Claim N/A
065240 ISO Address Command N/A
126208 NMEA N/A
Maretron Proprietary PGNs 128720 Configuration N/A