Maretron RAA100 Przewodnik Instalacji

Przeglądaj online lub pobierz Przewodnik Instalacji dla Elementy urządzeń bezpieczeństwa Maretron RAA100. Maretron RAA100 Installation guide Instrukcja obsługi

  • Pobierz
  • Dodaj do moich podręczników
  • Drukuj

Podsumowanie treści

Strona 1 - PRODUCT CATALOG 2010

2010PRODUCT CATALOG 2010

Strona 2

www.maretron.com 1-866-550-910010Maretron’s USB100 is a gateway for bridging computers to an NMEA network. This allows you to use PC based vessel m

Strona 3 - Contents

Copyright 2009 Maretron, LLP. All rights reserved. As Maretron is constantly improving its products, all specifications are subject to change without n

Strona 4 - Resistor

Displays & Alarms• DSM250• ALM10012Maretron offers a multi-function color display that can be used at multiple locations throughout the vessel. Th

Strona 5

Barometric Pressure Graph Course Up Heading Single Numeric DepthQuad Numeric Rolling Road Swing MeterTri-Display Local Weather Wind Speed and Directio

Strona 6 - Interfacing

www.maretron.com 1-866-550-910014DSM250Multi-Function Color DisplayMaretron’s DSM250 is a high-resolution sunlight viewable color display that allo

Strona 7

Copyright 2009 Maretron, LLP. All rights reserved. As Maretron is constantly improving its products, all specifications are subject to change without n

Strona 8

www.maretron.com 1-866-550-910016ALM100• NMEA 2000® Network Interface• Super loud 105dB audible alarm• Bright Red LED visual alarm• Green LED s

Strona 9

Copyright 2009 Maretron, LLP. All rights reserved. As Maretron is constantly improving its products, all specifications are subject to change without n

Strona 10 - Products

NavigationInstruments• WSO100• SSC200• GPS200• DST100Maretron brings you state-of-the-art, award-winning navigation instruments.Take our compass, for

Strona 12 - & Alarms

www.maretron.com

Strona 13

www.maretron.com 1-866-550-910020Maretron’s outdoor weather station measures wind speed and direction, air temperature, barometric pressure, and re

Strona 14

Copyright 2009 Maretron, LLP. All rights reserved. As Maretron is constantly improving its products, all specifications are subject to change without n

Strona 15 - Parameter Value

www.maretron.com 1-866-550-910022Maretron’s SSC200 is a solid state, rate gyro electronic compass that provides better than 1° heading accuracy thr

Strona 16

Copyright 2009 Maretron, LLP. All rights reserved. As Maretron is constantly improving its products, all specifications are subject to change without n

Strona 17 - Electrical

www.maretron.com 1-866-550-910024Maretron’s GPS200 is a state-of-the-art 32 channel GPS antenna and reciever capable of producing five position fix

Strona 18 - Instruments

Copyright 2009 Maretron, LLP. All rights reserved. As Maretron is constantly improving its products, all specifications are subject to change without n

Strona 19

www.maretron.com 1-866-550-910026Maretron’s DST100 Smart™ Retractable Depth/ Speed/Temperature Transducer, delivers precise digital depth, accurate

Strona 20 - Ultrasonic Wind

Copyright 2009 Maretron, LLP. All rights reserved. As Maretron is constantly improving its products, all specifications are subject to change without n

Strona 21 - DSM250 Screen Shots

Engine / VesselMonitoring• J2K100• EMS100• TLA100• RAA100• ACM100• DCM100• SIM100• RIM100• TMP100• TLM100• TLM150• TLM200Maretron brings you plug-and-

Strona 23

Maretron designs, manufactures and markets leading- edge networked electronics for the marine marketplace. Maretron’s products are desig

Strona 24

www.maretron.com 1-866-550-910030Maretron’s J2K100 attaches directly into J1939 networks of compatible engines, transmissions, and gensets and conv

Strona 25

Copyright 2009 Maretron, LLP. All rights reserved. As Maretron is constantly improving its products, all specifications are subject to change without n

Strona 26

www.maretron.com 1-866-550-910032Maretron’s EMS100 plugs directly into engine wiring harnesses and converts analog signals such as water temperatur

Strona 27 - Default Rate

Copyright 2009 Maretron, LLP. All rights reserved. As Maretron is constantly improving its products, all specifications are subject to change without n

Strona 28 - Monitoring

www.maretron.com 1-866-550-910034The TLA100 is used to adapt commercially available resistive tank senders to the NMEA 2000® network. This allows y

Strona 29

Copyright 2009 Maretron, LLP. All rights reserved. As Maretron is constantly improving its products, all specifications are subject to change without n

Strona 30 - J1939 to NMEA 2000

www.maretron.com 1-866-550-910036Maretron’s RAA100 is used to adapt commercially available resistive rudder senders to the NMEA 2000® network. This

Strona 31 - Standard Comment

Copyright 2009 Maretron, LLP. All rights reserved. As Maretron is constantly improving its products, all specifications are subject to change without n

Strona 32

www.maretron.com 1-866-550-910038ACM100Alternating Current MonitorMaretron’s ACM100 is a device which monitors AC power sources and outputs informa

Strona 33 - Protocol PGNs

Copyright 2009 Maretron, LLP. All rights reserved. As Maretron is constantly improving its products, all specifications are subject to change without n

Strona 34

World-class standards in navigational and vessel monitoring electronics.Simpler, safer boating. Freedom of choice. Those are the guiding principles

Strona 35

www.maretron.com 1-866-550-910040DCM100Direct Current MonitorMaretron’s DCM100 Monitor is an advanced electronic monitoring device used to measure

Strona 36

Copyright 2009 Maretron, LLP. All rights reserved. As Maretron is constantly improving its products, all specifications are subject to change without n

Strona 37

www.maretron.com 1-866-550-910042SIM100Switch Indicator ModuleMaretron’s Switch Indicator Module monitors switch closure devices including, but not

Strona 38

Copyright 2009 Maretron, LLP. All rights reserved. As Maretron is constantly improving its products, all specifications are subject to change without n

Strona 39

www.maretron.com 1-866-550-910044RIM100Run Indicator ModuleMaretron’s Run Indicator Module monitors both AC and DC electrical circuits and reports,

Strona 40

Copyright 2009 Maretron, LLP. All rights reserved. As Maretron is constantly improving its products, all specifications are subject to change without n

Strona 41 - Certifications

www.maretron.com 1-866-550-910046TMP100Temperature ModuleMaretron’s TMP100 measures the temperature for up to 6 temperature probes and reports the

Strona 42

Copyright 2009 Maretron, LLP. All rights reserved. As Maretron is constantly improving its products, all specifications are subject to change without n

Strona 43

www.maretron.com 1-866-550-910048TLM100Tank Level Monitor (40” Depth)Maretron’s TLM100 is used to sense fluid levels of tanks by using ultrasonic t

Strona 44

Copyright 2009 Maretron, LLP. All rights reserved. As Maretron is constantly improving its products, all specifications are subject to change without n

Strona 45

Maretron’s SSC200 is a solid state rate gyro compass with no moving parts and, unlike a flux gate compass that sloshes around during turns or pitching

Strona 46

www.maretron.com 1-866-550-9100Maretron’s TLM150 is used to sense gasoline fluid levels of tanks using ultrasonic technology. Ultrasonic, or sound

Strona 47

Copyright 2009 Maretron, LLP. All rights reserved. As Maretron is constantly improving its products, all specifications are subject to change without n

Strona 48

www.maretron.com 1-866-550-9100Maretron’s TLM200 is used to sense fluid levels of tanks using ultrasonic technology. Ultrasonic, or sound waves, ar

Strona 49

Copyright 2009 Maretron, LLP. All rights reserved. As Maretron is constantly improving its products, all specifications are subject to change without n

Strona 50

Maretron NMEA 2000®Cables & ConnectorsAbout NMEA 2000® Cables and ConnectorsThe NMEA 2000® standard goes beyond defining message content and inclu

Strona 51

Maretron NMEA 2000® Cable Features• Simple trunk and drop line topology interconnects all NMEA 2000® equipment• Drop line topology allows powered co

Strona 52

www.maretron.comCopyright 2009 Maretron, LLP. All rights reserved. As Maretron is constantly improving its products, all specifications are subject to

Strona 53

DETAIL "A"LABEL DETAIL(CONTACT HOLDER REMOVED)WIRE SIDE VIEWOF CONTACT HOLDERTO SHOW LABEL DETAILS(SCALE 2:1)REDBLACKWHITEGRAYBLUE55 mm2.17”

Strona 54 - Connectors

www.maretron.comCopyright 2009 Maretron, LLP. All rights reserved. As Maretron is constantly improving its products, all specifications are subject to

Strona 55 - Network Example

FEMALE END VIEW4. White(Net-H) 1. Bare(Shield)2. Red(Net-S)4. White(Net-H) 1. Bare(Shield)2. Red(Net-S)3. Black(Net-C)5. Blue(Net-L)3. Black(Net-C)5.

Strona 56 - MICRO/MID

• N2KView®• USB100PC Software/ Interfacing6

Strona 57 - Products Products

www.maretron.comCopyright 2009 Maretron, LLP. All rights reserved. As Maretron is constantly improving its products, all specifications are subject to

Strona 58 - Micro Double-Ended

FEMALE END VIEW4. White(Net-H) 1. Bare(Shield)2. Red(Net-S)4. White(Net-H) 1. Bare(Shield)2. Red(Net-S)3. Black(Net-C)5. Blue(Net-L)3. Black(Net-C)5.

Strona 59 - Cordsets

www.maretron.comCopyright 2009 Maretron, LLP. All rights reserved. As Maretron is constantly improving its products, all specifications are subject to

Strona 60

FEMALE END VIEW4. White(Net-H) 1. Bare(Shield)2. Red(Net-S)4. White(Net-H) 1. Bare(Shield)2. Red(Net-S)3. Black(Net-C)5. Blue(Net-L)3. Black(Net-C)5.

Strona 61 - MALE END VIEW

www.maretron.comCopyright 2009 Maretron, LLP. All rights reserved. As Maretron is constantly improving its products, all specifications are subject to

Strona 62

SpecificationsSpecificationsSpecificationsProductsProductsProducts MECHANICAL Molded Body Mat/Color: Thermoplastic PUR/Gray Contact Carrier Mat/Colo

Strona 63

www.maretron.comCopyright 2009 Maretron, LLP. All rights reserved. As Maretron is constantly improving its products, all specifications are subject to

Strona 64

FEMALE END VIEWMALE END VIEW88.0 [3.46]10-12mmCABLE DIAMETER 7/8-16Ø27.0 [1.06]78.5 [3.09]Ø27.0 [1.06]7/8-16UN10-12mmCABLE DIAMETERMini Bulk Cable (Gr

Strona 65

www.maretron.comCopyright 2009 Maretron, LLP. All rights reserved. As Maretron is constantly improving its products, all specifications are subject to

Strona 66

17.5 [0.69]28.0 [1.10]28.0 [1.10]17.5 [0.69]7/8-16UN 7/8-16UN7/8-16 UN73.0 [2.87]CLEARANCE FOR#8 (M4) FASTENERØ26.0 [1.02]Ø26.0 [1.02]17.5 [0.69]28.0

Strona 67

Maretron brings world-class vessel monitoring systems to the PC using state of the art networking technology. Now you can monitor all critical vessel

Strona 68 - Cordset (Blue)

www.maretron.comCopyright 2009 Maretron, LLP. All rights reserved. As Maretron is constantly improving its products, all specifications are subject to

Strona 69

1.472 [37.4]2.100 [53.3]CLEARANCE FOR#8 FASTENER (M4)Ø1.024 [26.0]7/8-16UN7/8-16UNØ1.024 [26.0]Ø1.102 [28.0]38.2 [1.50]17.5 [0.69]Mini Termination Res

Strona 70

www.maretron.comCopyright 2009 Maretron, LLP. All rights reserved. As Maretron is constantly improving its products, all specifications are subject to

Strona 71

30.4 [1.20]27.0 [1.06]LOCKWASHERSEE NOTE 1LOCKNUTTHRUSTWASHERSEALINGGASKET7/8-16UN49.3 [1.94]32.7 [1.29]7/8-16UNFEMALE END VIEWMALE END VIEW73.0 [2.87

Strona 72 - (Male/Male)(Female/Female)

Maretron NMEA 2000®Network Installation GuideInstalling an NMEA 2000® NetworkInstalling an NMEA 2000® network consists of inter-connecting NMEA

Strona 73

opposed to Micro cable (4 amps). Mini cable has an outside diameter in the range from 0.41 to 0.49 inches. Its maximum installed bend radius is 7x the

Strona 74 - Maretron NMEA 2000

For most cases, the maximum distance should be measured between termination resistors. However, if the distance from a trunk line tee to the farthest

Strona 75 - Figure 2

Figure 4Mini PowertapFigure 5Micro/Mid Powertap1.7 NMEA 2000® ConnectorsConnectors attach cables to devices or other components of the NMEA 2000® cabl

Strona 76 - Figure 3

Powertap can handle large loads as long as no more than 8 amps is drawn through any single segment of the trunk line. However, cable resistance may li

Strona 77 - Figure 5

location. Grounding at more than one location may produce ground loops, which can cause problems with communications on the network. In

Strona 78 - Figure 6

www.maretron.com 1-866-550-9100Electrical Systems ViewEngineView8N2KView®Vessel Monitoring and Control SoftwareN2KView® is completely user-configu

Strona 79 - Figure 7

www.maretron.com 1-866-550-910080N2KBuilder™ NMEA 2000® Network Design SoftwareN2KBuilder™ software is a powerful, free PC-based tool for designing

Strona 80 - N2KBuilder

Copyright 2009 Maretron, LLP. All rights reserved. As Maretron is constantly improving its products, all specifications are subject to change without n

Strona 81 - N2KAnalyzer

Maretron Corporate Office9014 N. 23rd Avenue, Suite 10Phoenix, AZ 85021Toll Free: 866-550-9100Phone: 602-861-1707Fax: 602-861-1777Email: sales@maretro

Strona 82

Copyright 2009 Maretron, LLP. All rights reserved. As Maretron is constantly improving its products, all specifications are subject to change without n

Komentarze do niniejszej Instrukcji

Brak uwag