Maretron USB100 Instrukcja Użytkownika

Przeglądaj online lub pobierz Instrukcja Użytkownika dla Bramy / kontrolery Maretron USB100. Proper NMEA 2000 Installation IBEX 2012 Session 813 Instrukcja obsługi

  • Pobierz
  • Dodaj do moich podręczników
  • Drukuj

Podsumowanie treści

Strona 1 - IBEX 2012 Session 813

Proper NMEA 2000 Installation IBEX 2012 Session 813 Part I Physical Installation Dave Morschhauser, Mystic Valley Communications Pete Braffitt, Gemeco

Strona 2 - Overview

Physical Construction • Building Blocks • Characteristics • Power Availability • Other considerations

Strona 3 - NMEA 2000

NMEA 2000 Building Blocks Power Tee(s) Tee Connectors Termination Resistors Backbone & Drop Cables

Strona 4 - NMEA 2000 Certification

NMEA 2000 Building Blocks Mini to Micro Adapter Mini Backbone w/ Micro Drop Gender Changer Field Installable Connectors

Strona 5

NMEA 2000 Characteristics Overall: • Capacity - 250K bits-per-second • Interface operating range - 9 to 15 volts • Logical network identities - 252 •

Strona 6 - Typical Tee

NMEA 2000 Characteristics Each backbone: • Length - 200 meters – 100 meters when using light cable • Connected products - 50 • Drop cable – 6 meters

Strona 7

NMEA 2000 Terminology Backbone Length Drop Length Power Insertion Point Backbone Length Segment

Strona 8 - NMEA 2000 = Vessel Database

Cable Construction Shield / Drain NET-S NET-C NET-H NET-L Name Pair Color Shield Drain Bare NET-L Data Blue NET-H Data White NET-C Power - B

Strona 9

Product Power Sources

Strona 10 - Physical Construction

Cable Types Style Light Mid Heavy Connectors Micro Micro/Mini Mini Max Length 100 meters 200 meters 200 meters Capacity 3 amp* 4/8 amp* 8*

Strona 12

Overview • What is NMEA 2000? • What are its physical characteristics and limits? • What makes a good NMEA 2000 network? • What makes a good NMEA 2000

Strona 13 - NMEA 2000 Characteristics

NMEA 2000 Backbone Single Backbone Two Segments

Strona 14

Power Sources • Battery (nominally 12.0 VDC) – Allowed voltage drop = 1.5 VDC • Typical power supply (13.8 VDC) – Allowed voltage drop = 3.0 VDC • Max

Strona 15 - NMEA 2000 Terminology

Other Considerations • Products may be added to or removed from the backbone while operational • No daisy-chaining ensures backbone remains intact whe

Strona 16 - Cable Construction

Making the Right Selections

Strona 17 - Product Power Sources

Network Design Drivers • Network power distribution – Segment voltage drop limit – Add power insertions points as needed • Network topology – Keep it

Strona 18 - Cable Types

Network Voltage Drop • Straightforward application of Ohm’s Law where E = voltage drop I = circuit current R = wire resistance E = I x R

Strona 19 - NMEA 2000 Backbone

Network Voltage Drop • Wire resistance • Network current • All together R = 2 x Length x Power Pair Resistance / 100 I = LEN x 0.050 amp E = 0.1 x

Strona 20

Estimated Length - Light 010203040506070081624324048566472808896LengthTotal LENVD = 1.5 VoltsVD = 3.0 VoltsVD = 5.0 Volts

Strona 21 - Power Sources

Example Network 2 Meters 5 Meters 6 Meters 3 LEN 6 Meters 2 LEN 6 Meters 5 LEN 3 Meters Termination Resistor Termination Resistor

Strona 22 - Other Considerations

Example Summary • Total load = 10 LEN • Backbone length = 13 meters • Using light cable – Power pair resistance = 0.057 Ω/meter E = 0.1 x 10 x 13 x 0.

Strona 23 - Making the Right Selections

NMEA 2000 • Marine specific network for navigation, control, and monitoring • CAN based, similar to J1939 • Uses industrial quality cabling originally

Strona 24 - Network Design Drivers

Estimated Length - Light 010203040506070081624324048566472808896LengthTotal LENVD = 1.5 VoltsVD = 3.0 VoltsVD = 5.0 VoltsLEN = 25 Length = 18

Strona 25 - Network Voltage Drop

Network Layout • ‘Trunk and Drop’ Topology • Determine location for each product • Determine path for trunk/backbone that: – Passes within 6 meters of

Strona 26

Network Layout

Strona 27 - Estimated Length - Light

Layout Issues • Multiple connections in confined spaces • Sailboat masts & powerboat towers • Gateways to other protocols • Multiple backbone conf

Strona 28 - Example Network

Multiple Connections in Confined Spaces • Multi-tap tee is used just like multiple tees • Multi-drop splitter has some limitations

Strona 29 - Example Summary

Multi-tap Drop Power Tee 4-way Tap Drop Cable (6 Meters max length) Drop Cable (x Meters) 6-x Meters 6-x Meters 6-x Meters Termination Resistor Ter

Strona 30

Sailboat Masts • Most masts are greater than 6 Meters • Backbone termination at the top of the mast • In-Line termination resistors are used • Must b

Strona 31 - Network Layout

Gateways NMEA 2000 0183 Gateway DSC VHF NMEA 2000 GPS information is sent to VHF radio for DSC broadcast Termination Resistor Termination Resistor

Strona 32

Gateways NMEA 2000 J1939 Gateway J1939 data is converted and transmitted on the NMEA 2000 Network Termination Resistor Termination Resistor Proprieta

Strona 33 - Layout Issues

NMEA 2000 Network Bridge • Connect two networks • > 50 nodes • Backbone > 200 meters • Drops > 78 meters • Separate mast backbone from main •

Strona 34 - Multiple Connections

NMEA 2000 Certification • First certification program applicable to recreational marine electronic products • Over 400 products certified to date • Pu

Strona 35 - Multi-tap Drop

Power Insertion • How many insertion points? • Common reference point • Connect shield to RF ground only once • Each leg has only one power source – c

Strona 36 - Sailboat Masts

Power Insertion Shield/Drain left unconnected at all other insertion points

Strona 37 - Gateways

Power Insertion Building Blocks

Strona 38

Testing

Strona 39 - NMEA 2000 Network Bridge

Testing Checklist • Loose connections • Voltage fluctuations & data errors – Voltage consistent and > 9 VDC at all tees • Correct termination –

Strona 40 - Power Insertion

Testing Checklist • 50 connected products or less • Drops 6 meters or less • Total drops 78 meters or less • Network 200 meters or less • All power ta

Strona 41

Plug and Play Limitation • Layout and power planning rules result in products communicating non-destructively • Product configuration ensures data dis

Strona 42

Acknowledgements and Contact Information Photos courtesy of Airmar, Actisense, Garmin, LTW, Maretron, Molex, Turck Diagrams courtesy NMEA Contact In

Strona 43 - Testing

NMEA Software Utilities

Strona 44 - Testing Checklist

Actisense NMEA Reader • The Actisense NMEA Reader is a great utility for testing and evaluating a NMEA 0183 or NMEA 2000™ system. • The program is

Strona 45

NMEA 2000

Strona 46 - Plug and Play Limitation

• The Actisense NGT-1-USB is a great product to deliver NMEA 2000™ data directly into the PC for use with the NMEA Reader Software. Actisense NMEA Rea

Strona 47 - Acknowledgements

Actisense NMEA Reader • The NMEA Reader is a good utility to read what sentences are located on the network. • The data shown includes the specific P

Strona 48 - NMEA Software Utilities

Actisense NMEA Reader • The top selected item shows the com port, description and baud rate of the available NMEA 0183 or NMEA 2000™ Device.

Strona 49 - Actisense NMEA Reader

Actisense NMEA Reader • The interval shows how often the data is being sent from the device. This allows the user to know how fast a sender is transm

Strona 50

Actisense NMEA Reader • Pictured here are the details of each individual data PGN. • This will list what data is present on the specific device as wel

Strona 51

Actisense NMEA Reader • The bus load can be used to check how many devices on the network. • If the NMEA 2000™ network is not functioning correctly i

Strona 52

Actisense NMEA Reader

Strona 53

Actisense NMEA Reader • This item shows which instance is assigned to the device allowing for the user to match it on the display. • Also pictured ar

Strona 54

Actisense NMEA Reader

Strona 55

Sail Soft NEMA Studio • The Sail Soft program will allow data to be sent from a PC via NMEA 0183 on a user selected Com Port. • This will allow for t

Strona 56

Typical Tee Drop Connection to device (FEMALE)- Accepts drop cable. MALE Backbone Connection FEMALE Backbone Connection

Strona 57

• The Actisense NGW-1 is a great way to convert the data sent from the Sail Soft program into a NMEA 2000™ Format. It can also send AIS information i

Strona 58

Sail Soft NEMA Studio

Strona 60

Sail Soft NEMA Studio

Strona 61

• The Maretron N2KAnalyzer Software is free to download from the Maretron Web site and offers many valuable options for network evaluation and testing

Strona 62

Maretron N2KAnalyzer • The Maretron USB100 Gateway will allow the NMEA 2000™ network to be accessed by the N2KAnalyzer to show what devices are attach

Strona 63

• The Main Device page will show what devices are connected to the Network and the specific information of that device. Maretron N2KAnalyzer N2KAnalyz

Strona 64 - Maretron N2KAnalyzer

• The unique instance tab allows for the user to view and assign specific instances to a sender if there are multiple versions of the same unit on the

Strona 65

• The Instancing tool is as simple as setting the number for any applicable device. Maretron N2KAnalyzer N2K Analyzer Software Device Page

Strona 66

Maretron N2KAnalyzer N2KAnalyzer Software Properties Page The PGN Page shows all transmitted and received sentences to ensure proper operation.

Strona 67

NMEA 2000 • Single backbone cable snakes throughout the vessel • No active network infrastructure to fail • Standardized message structure and format

Strona 68

Maretron N2KAnalyzer N2KAnalyzer Software Properties Page The Received PGN Page shows the specifics of what data is being sent and specifics of that d

Strona 69

Maretron N2KAnalyzer N2KAnalyzer Software Properties Page The transmitted PGN Page will allow for the user to view the live data coming from a sensor

Strona 70

Maretron N2KAnalyzer N2KAnalyzer Software Properties Page N2KAnalyzer also offers the ability to simulate a DSM250 display through the software to vie

Strona 71

Maretron N2KBuilder • Maretron’s unique N2KBuilder program allows dealers and installers to design and test networks before any cable is pulled throug

Strona 72

Maretron N2KBuilder

Strona 74

Maretron N2KBuilder • This build file shows a system where the end user supplies specifics to be used to generate a complete network. It is a useful

Strona 75

Maretron N2KBuilder • Attached is a detailed view of how the system can be used to partition specific sections of a vessel and show possible connectio

Strona 76

Maretron N2KBuilder • The Bill of Materials that is generated from the Builder file is an excellent way to control cost of the build as well as to gen

Strona 77

Maretron N2KMeter • The N2KMeter has the capability to test the physical aspects of a network. • Faults that can be detected by the N2KMeter includ

Strona 78

NMEA 2000 = Vessel Database

Strona 79 - Maretron N2KMeter

Maretron N2KMeter • The meter offers the ability to use an Auto-Search tool that will allow the dealer to locate faults. • It works by examining all m

Strona 80

Maretron N2KMeter • The automated error detection of the N2KMeter allows the user to view issues on the backbone live. • The technician will be able t

Strona 81

Maretron N2KMeter • Any error rate greater than zero is undesirable (although your network may still function since CAN automatically retransmits afte

Strona 82

What can you do with NMEA 2000?

Komentarze do niniejszej Instrukcji

Brak uwag