13.6.3 Configuring Loads
These are edited on the Load Shedding Dialog.
Individual Loads may be configured to be included or excluded from the Load
Shedding by checking the Enabled box.
The Panel Instance and Breaker Channel are set by the user to identify which
breaker is to be switched to shed the load.
The Current Drawn is set by the user to inform the algorithm how much current
will be shed or restored by switching this load.
The Breaker Status is reported by the system in real time so that the user can
see the current state of the breaker. Values are “Off”, “On”, “Locked Off”,
“Locked On”, “Load Shed”, “Tripped” and “Unknown”